044 28440990 srpharma@gmail.com

Elisa Test Kits

HIV RANGE

MICROLISA HIV

INTENDED USE
MICROLISA HIV is an in-vitro qualitative enzyme immunoassay for the detection of antibodies to HIV-1 and /or HIV-2 in human serum or plasma. It is intended for screening of blood donors or other individuals at risk for HIV-1 and HIV-2 infection and for clinical diagnostic testing.

SALIENT FEATURES

  • Use of Envelope Antigens gp41,C terminus of gp120 for HIV-1& gp36 for HIV-2.
  • Detection of Group O & subtype C for HIV-1 prevalent in India.
  • Color coded reagents to monitor procedural steps.
  • Assay procedure: 90mins.
  • Longer shelf life: 15 months at 2-8°C.
  • Sensitivity & Specificity of 100% by WHO.

4TH GENERATION MICROLISA HIV Ag & Ab

INTENDED USE
4TH GENERATION MICROLISA HIV Ag & Ab is an in- vitro qualitative enzyme immunoassay for the detection of antibodies to HIV-1 and/or HIV-2 and HIV-1 p24 antigen in human serum or plasma. It is intended for screening of blood donors or other individuals at risk for HIV-1 and/or HIV-2 infection and for clinical diagnostic testing.

SALIENT FEATURES

  • Use of Envelope Antigens gp41, C terminus of gp120 for HIV-1 and gp36 for HIV-2
    & simultaneously detection of p24 antigen with p24 monoclonal antibodies
  • Detection of Group O & subtype C for HIV-1 prevalent in India
  • Colour coded reagents to monitor the procedural steps
  • Assay procedure: 120 mins
  • Shelf life: 12 months at 2-8°C
  • Sensitivity 100% & Specificity 99.97%
  • Significant reduction in window period
  • Easy to use on automated and semi-automatic processor

HCV RANGE

HCV MICROLISA

INTENDED USE
The 3rd generation HCV Microlisa is an in vitro qualitative enzyme linked immunosorbent assay for the detection of antibodies against HCV (anti-HCVs) in human serum or plasma. The kit is basically intended to screen blood donations to identify and eliminate the infected units of blood and for clinical diagnostic testing.

SALIENT FEATURES

  • 3rd Generation Assay
  • Unique combination of HCV antigens for E1, E2, Core, NS3, NS4 & NS5
  • Break-away microwell strips
  • Based on Indirect Elisa principle
  • Colour coded reagents to monitor procedural steps.
  • Short assay procedure: 90mins
  • Longer shelf life: 15 months at 2-8°C.
  • Sensitivity 100% & Specificity 97.4% by WHO.

HBV RANGE

HEPALISA

INTENDED USE
HEPALISA is designed for in – vitro qualitative detection of Hepatitis B Surface antigen (HBsAg) in human serum or plasma and is used as a screening test for testing of collected blood prior to transfusion.

SALIENT FEATURES

  • Detects all the known 11-subtypes of HBV
  • Antigen Sensitivity-0.1ng/ml.
  • Two step Immunoassay.
  • Short protocol: Based on single washing step.
  • Assay Procedure: 90 mins.
  • Shelf life-15 months at 2-8°C.
  • Convenient pack size :96 tests
  • Break-away wells for minimal wastage
  • Easy interpretation of result
  • Sensitivity & Specificity 100% by WHO.

HEPALISA ULTRA

INTENDED USE
Hepalisa Ultra is designed for in-vitro qualitative detection of Hepatitis B Surface antigen (HBsAg) in human serum or plasma and is used as a screening test for testing of collected blood prior to transfusion.

SALIENT FEATURES

  • 4thGeneration HBsAg detection kit
  • Based on Direct Sandwich principle
  • Detects all the known 11 subtypes of HBV and also mutant strains
  • Antigen sensitivity: 0.05 ng/ml
  • Ready to use conjugate
  • Easy Interpretation of results
  • Shelf life 12 Months, Storage at 2-8°C
  • Available in convenient Packsize of 96 Tests
  • Specificity: Increased power of discrimination between positive & negative samples.

DENGUE RANGE

DENGUE IgG MICROLISA

INTENDED USE
DENGUE IgG Microlisa is designed for in-vitro qualitative detection of Dengue IgG antibodies in human serum or plasma and is used as a screening test for testing of collected blood samples suspected for DENGUE. The kit detects all four subtypes; DEN1, DEN2, DEN3 & DEN4 of Dengue Virus.

SALIENT FEATURES

  • Based on “CAPTURE ELISA” principle
  • Detection of all 4 serotypes of Dengue (DEN 1 – DEN 4)
  • Colour coded reagents to monitor procedural steps
  • Longer Shelf life: 12 months at 2-8°C
  • Sensitivity 96.00% & Specificity 99.93%
  • Convenient pack size: 48 Tests
  • Unique break-away wells
  • Prompt service back up

DENGUE IgM MICROLISA

INTENDED USE
DENGUE IgM MICROLISA is designed for in-vitro qualitative detection of Dengue IgM antibodies in human serum or Plasma and is used as a screening test for testing of collected blood samples suspected for DENGUE. The kit detects all four subtypes; DEN1, DEN2, DEN3 & DEN4 of Dengue Virus.

SALIENT FEATURES

  • Based on “Capture ELISA” principle
  • Detection of all 4 serotypes of Dengue (DEN 1 – DEN 4).
  • Colour coded reagents to monitor procedural steps.
  • Longer Shelf life: 12 months at 2-8°C.
  • Sensitivity 99.13% & Specificity 99.84%
  • Convenient pack size: 48 Tests
  • Unique break-away wells
  • Prompt service back-up

Dengue NS1 Ag Microlisa

INTENDED USE
DENGUE NS1 Ag MICROLISA is designed for in vitro qualitative detection of Dengue NS1 antigen in human serum or plasma and is used as a screening test for testing of collected blood samples suspected for DENGUE. The kit detects all four subtypes; DEN1, DEN2, DEN3 & DEN4 of Dengue Virus.

SALIENT FEATURES

  • First line testing kit for detecting infection with Dengue NS1 Ag.
  • Based on Direct Sandwich Elisa principle
  • Detection of all 4 serotypes of Dengue (DEN 1 – DEN 4)
  • Color coded reagents to monitor procedural steps
  • Significant reduction in window period
  • Longer Shelf life: 12 months at 2-8°C.
  • Sensitivity 99.50% & Specificity 100%.
  • Convenient Packsize: 48 tests

LEPTO RANGE

LEPTO IgM MICROLISA

INTENDED USE
LEPTO IgM MICROLISA is designed for in-vitro qualitative detection of Leptospira IgM in human serum or plasma and it is used as a screening test for testing of collected blood samples suspected for Leptospirosis.

SALIENT FEATURES

  • Based on Indirect Elisa principle
  • Colour coded reagents to monitor procedural steps
  • Test procedure: 90 mins
  • Longer Shelf life: 12 months at 2-8°C
  • Excellent Sensitivity 99.22% & Specificity 99.84%
  • Unique break-away wells
  • Easy to use on automated & semi automated processor